{"id":20748,"date":"2022-06-18T13:58:05","date_gmt":"2022-06-18T20:58:05","guid":{"rendered":"https:\/\/www.globalpwr.com\/?post_type=product&#038;p=20748"},"modified":"2025-11-26T05:10:17","modified_gmt":"2025-11-26T13:10:17","slug":"liebert-apm-60-kva","status":"publish","type":"product","link":"https:\/\/www.globalpwr.com\/ups-system\/liebert-apm-60-kva\/","title":{"rendered":"Liebert APM 60 kVA"},"content":{"rendered":"<table class=\"detailtbl\" border=\"0\">\n<tbody>\n<tr>\n<td class=\"ttitle\" colspan=\"2\">\n<h3 class=\"detailsec\">UPS Details<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">SKU<\/td>\n<td class=\"tright\">6440<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Manufacturer<\/td>\n<td class=\"tright\">Liebert<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Condition<\/td>\n<td class=\"tright\">Used<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Year<\/td>\n<td class=\"tright\">2013<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Model<\/td>\n<td class=\"tright\">NRD90CCSA0A4000<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Model Family<\/td>\n<td class=\"tright\">APM<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Serial Number<\/td>\n<td class=\"tright\">M13C3F0014<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">kW<\/td>\n<td class=\"tright\">60<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">kVA<\/td>\n<td class=\"tright\">60<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Phase<\/td>\n<td class=\"tright\">3<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Input Voltage<\/td>\n<td class=\"tright\">120\/208<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Output Voltage<\/td>\n<td class=\"tright\">120\/208<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Input Wiring<\/td>\n<td class=\"tright\">4 wire<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Output Wiring<\/td>\n<td class=\"tright\">4 wire<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Maintenance Bypass<\/td>\n<td class=\"tright\">Yes<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Lead Time (Weeks)<\/td>\n<td class=\"tright\">1 to 2<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">DC Amps<\/td>\n<td class=\"tright\">332<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">DC Bus Voltage<\/td>\n<td class=\"tright\">288<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Input Amperage Max<\/td>\n<td class=\"tright\">300<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Input Frequency<\/td>\n<td class=\"tright\">60 Hz<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Output Amps Max<\/td>\n<td class=\"tright\">250<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Output Frequency<\/td>\n<td class=\"tright\">60 Hz<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Bypass Amps Max<\/td>\n<td class=\"tright\">250<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Bypass Voltage<\/td>\n<td class=\"tright\">120\/208<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Bypass Wiring<\/td>\n<td class=\"tright\">4 wire<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Length\/Depth (Inches)<\/td>\n<td class=\"tright\">41<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Width (Inches)<\/td>\n<td class=\"tright\">32<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Height (Inches)<\/td>\n<td class=\"tright\">79<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Weight (Lbs)<\/td>\n<td class=\"tright\">1260<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">ID#<\/td>\n<td class=\"tright\">20748<\/td>\n<\/tr>\n<tr>\n<td class=\"ttitle\" colspan=\"2\">\n<h3 class=\"detailsec\">Battery Details<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Battery System<\/td>\n<td class=\"tright\">External<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">External Batteries<\/td>\n<td class=\"tright\">Yes<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Batteries Included<\/td>\n<td class=\"tright\">N<\/td>\n<\/tr>\n<tr>\n<td class=\"tleft\">Battery Type<\/td>\n<td class=\"tright\">Lead Acid<\/td>\n<\/tr>\n<tr>\n<td class=\"ttitle\" colspan=\"2\">\n<h3 class=\"detailsec\">Notes<\/h3>\n<\/td>\n<\/tr>\n<tr>\n<td class=\"nleft\" colspan=\"2\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"excerpt":{"rendered":"<p>UPS Details SKU 6440 Manufacturer Liebert Condition Used Year 2013 Model NRD90CCSA0A4000 Model Family APM Serial Number M13C3F0014 kW 60 kVA 60 Phase 3 Input Voltage 120\/208 Output Voltage 120\/208 Input Wiring 4 wire Output Wiring 4 wire Maintenance Bypass Yes Lead Time (Weeks) 1 to 2 DC Amps 332 DC Bus Voltage 288 Input\u00a0 &#8230;<\/p>\n","protected":false},"featured_media":0,"template":"","meta":{"_acf_changed":false,"_searchwp_excluded":"","inline_featured_image":false},"product_brand":[2299],"product_cat":[2234],"product_tag":[],"class_list":{"0":"post-20748","1":"product","2":"type-product","3":"status-publish","5":"product_brand-liebert","6":"product_cat-ups-system","7":"pa_condition-used","8":"pa_kva-2532","9":"pa_kw-2435","10":"pa_trailer-false","12":"first","13":"instock","14":"taxable","15":"shipping-taxable","16":"product-type-simple"},"bundle_layout":"","bundled_by":[],"bundled_items":[],"acf":[],"aioseo_notices":[],"_links":{"self":[{"href":"https:\/\/www.globalpwr.com\/wp-json\/wp\/v2\/product\/20748","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.globalpwr.com\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/www.globalpwr.com\/wp-json\/wp\/v2\/types\/product"}],"wp:attachment":[{"href":"https:\/\/www.globalpwr.com\/wp-json\/wp\/v2\/media?parent=20748"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/www.globalpwr.com\/wp-json\/wp\/v2\/product_brand?post=20748"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/www.globalpwr.com\/wp-json\/wp\/v2\/product_cat?post=20748"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/www.globalpwr.com\/wp-json\/wp\/v2\/product_tag?post=20748"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}